We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.

Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW

Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW
Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW
Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW
Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW
Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW
PLCAGE: Milliamp Process Clamp Meter FLUKEF773 FLUKE NEWFEATURES:Best in class 0.2 % accuracy0.01 mA... Read More
$983.00
Ex Tax: $983.00
  • Stock: In Stock
  • Model: FLUKEF773
  • Weight: 0.35kg
1. We typically ship items within three business days after payment is received.
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.

Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
We accept many payments,include Paypal,Bank Transfer etc
Tags: FLUKEF773
PLCAGE: Milliamp Process Clamp Meter FLUKEF773 FLUKE NEW

FEATURES:

Best in class 0.2 % accuracy0.01 mA resolution and sensitivityMeasure 4 to 20 mA signals without ”breaking the loop”Measure mA signals for PLC and control system analog I/ODual backlit display with both mA measurement and percent of 4 to 20 mA spanMeasurement Spotlight illuminates hard to see wires in dark enclosuresDetachable clamp with extension cable for measurements in tight locationsMeasure 10 to 50 mA signals in older control systems using the 99.9 mA rangeAutomatically change the 4 to 20 mA output for remote testingPower saving features, auto-off, backlight timeout extend battery lifeHold function captures and displays changing measurementsMeasure 4 to 20 mA signals with in-circuit measurementSimultaneous mA in-circuit measurement with 24V loop power for powering and testing transmittersSource 4 to 20 mA signals for testing control system I/O or I/PsmA output linear ramp or 25% step outputAutomatically change the 4 to 20 mA output for remote testingDC voltage measurement to verify 24V power supplies or voltage I/O signalsSource DC voltage to test input devices that accept a 1-5V or 0 to 10V signalsScaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clampEnables milliamp signal logging to a separate logging device without breaking the loopOutput mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loopmA in/out: simultaneously measure the mA signal with the clamp and source a mA signalApply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolatorsVoltage output linear ramp or 25% step outputAutomatically change the voltage output for remote testing

 

What’s the difference between the 77X models?                   

                       *

Fluke-771

Fluke-772

Fluke-773

                       *

Non-contact mA loop measurement

Integrated mA loop troubleshooting

Advanced process troubleshooting

mA measure, jaw

 

 

 

mA measure, in circuit               

                    *

 

 

Loop power

                    *

 

 

mA source

                    *

 

 

DCV measure

                    *

                    *

 

DCV source

                    *

                    *

 

mA scaled output                    

                    *

                    *

 

mA in / out

                    *

                    *

 

 

Environmental Specifications

Diameter of measurable conductor

0.177” or 4.5 mm max

Operating temperature

-10 to 50 ºC

Storage Temperature

-25 to 60ºC

Operating Humidity

< 90% @ <30 ºC, < 75% @ 30 to 55ºC

Operating Altitude

0 to 2000 m

IP Rating

IP 40

Size

44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)

Weight

410 g, (14.4 oz)

Vibration

Random 2 g, 5 to 500 Hz

Shock

1 meter drop test (except the jaw)

EMI/RFI

Meets EN61326-1 
            Note: For current measurement w/ JAW, add 1mA to 
            specification for EMC field strengths of 1V/m up to 3V/m.

Temperature Coefficient

0.01% ºC 
            (<18ºC or > 28ºC)

Power, battery life

(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms

Warranty

Three years for electronics 
            one year for cable and clamp assembly

 

Functional Specifications

mA measurement 
            (Measured by clamp) 771/772/773

Resolution and Range:          0 to 20.99 mA
            Accuracy:                 0.2%+2 counts
    Resolution and Range:          21.0 mA to 100.0 mA
            Accuracy:                   1% + 5 counts

mA measurement 
 (Measured in series with test jacks) 772/773

Resolution and Range:          0 to 24.00 mA
            Accuracy:             0.2% + 2counts

mA source (Maximum mA Drive: 
            24 mA into 1,000 ohms)

Resolution and Range:          0 to 24.00 mA
            Accuracy:             0.2% + 2counts

mA simulate 
            (Maximum voltage 50 V dc)

Resolution and Range:          0 to 24.00 mA
            Accuracy:             0.2% + 2counts

Voltage source (2 mA maximum drive current)

Resolution and Range:          0 to 10.00 V dc
            Accuracy:             0.2% + 2counts

Voltatge Mesaure

Resolution and Range:          0 to 30.00 V dc
          Accuracy:             0.2% + 2counts

 