FX3U-3A-ADP Mitsubishi PLC Special Adapter Original Brand NEWIntroductionThe FX3U-3A-ADP special ada... Read More
$287.00
Ex Tax: $287.00
  • Stock: In Stock
  • Model: FX3U-3A-ADP
  • Weight: 1.00kg
1. We typically ship items within three business days after payment is received.
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.

Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
We accept many payments,include Paypal,Bank Transfer etc
Tags: FX3U-3A-ADP

FX3U-3A-ADP Mitsubishi PLC Special Adapter Original Brand NEW


Introduction

The FX3U-3A-ADP special adapter for analog input and output (hereinafter called 3A-ADP) is a special adapter that adds to add two analog input points and one analog output point.

Applicable PLC

Model name

Applicability

FX3U Series PLC

Ver. 2.61 or later

FX3UC Series PLC

Ver. 2.61 or later

FX3G Series PLC

Ver. 1.20 or later

FX3GC Series PLC

Ver. 1.40 or later (from first production)

The version number can be checked by monitoring D8001/D8101 as the last three digits indicate it.

Power Supply Specifications

Item

Specification

Conversion circuit

driving power

24V DC +20% / -15%, 90mA

Connect a 24V DC power supply to the terminal block.

Interface driving

power

5V DC, 20mA

5V DC power is supplied from the internal power supply of main unit.

Performance Specifications

Performance Specifications of Analog Input

Item

Specification

Voltage input

Current input

Analog input range

0 to 10V DC (Input resistance: 198.7 k ohm)

4 to 20mA DC

(Input resistance: 250ohm)

Maximum

absolute input

-0.5V, +15V

-2mA, +30mA

Resolution

2.5mV (10V/4000)

5uA (16mA/3200)

Total accuracy

+-0.5% (+-50mV) for full scale

of 10V (when ambient

temperature is 25°C+-5°C)

+-1.0% (±100mV) for full scale

of 10V (when ambient

temperature is 0°C to 55°C)

+-0.5% (+-80uA) for full scale

of 16mA (when ambient

temperature is 25°C+-5°C)

+-1.0% (+-160uA) for full scale

of 16mA (when ambient

temperature is 0°C to 55°C)

Performance Specifications of Analog Output

Item

Specification

Voltage output

Current output

Analog output range

0 to 10 V DC

(External load: 5k ohm to 1M ohm)

4 to 20mA DC

(External load: 500 ohm or less)

Resolution

2.5mV (10V/4000)

4uA (16mA/4000)

Total

accuracy

+-0.5% (+-50mV) for full scale

of 10 V (when ambient

temperature is 25°C+-5 °C)

+-1.0% (+-100mV) for full

scale of 10 V (when ambient temperature is 0°C to 55°C)

If the external load resistance

(Rs) is less than 5k ohm, the accuracy will be increses as  shown in the following formula: (Addition will be 100mV per%.)

 

+-0.5% (+-80uA) for full scale

of 16mA (when ambient

temperature is 25°C±5°C)

+-1.0% (+-160uA) for full

scale of 16mA (when

ambient temperature is 0°C

to 55 °C)

Total accuracy

+-0.5% (+-50mV) for full scale

of 10V (when ambient

temperature is 25°C+-5°C)

+-1.0% (±100mV) for full scale

of 10V (when ambient

temperature is 0°C to 55°C)

+-0.5% (+-80uA) for full scale

of 16mA (when ambient

temperature is 25°C+-5°C)

+-1.0% (+-160uA) for full scale

of 16mA (when ambient

temperature is 0°C to 55°C)