Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: 6SE6400-0BP00-0AA0
- Weight: 1.00kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
Siemens Micromaster Basic Operator Panel BOP 6SE6400-0BP00-0AA0
Product Description:
With the BOP, individual parameter settings can be made. Values and units are shown on a 5-digit display. A BOP can be used for several inverters. It can be directly mounted on the inverter or in a control cabinet door using a mounting kit. Advanced Operator Panel (AOP).The AOP enables MICROMASTER 440 parameter kits to be easily read and modified. In contrast to the BOP, the value and meaning of the parameters can be directly displayed as plain text in several languages by fast scrolling of the address.
The AOP is directly plugged into the inverter, or communicates with the latter through a door mounting kit. Together with the “AOP door mounting kit for multiple inverters”, the AOP permits bus communication with up to 30 inverters at a transmission rate of 38 k baud. (RS485, USS). For servicing purposes, the AOP furthermore supports the download and up read of complete parameter kits. The AAOP is the Chinese version of the AOP operator pan-el. It has an enhanced display and supports the operating languages of Chinese (simplified) and English.
The pulse encoder evaluation module permits direct connection of the most widely en-countered digital pulse en-coders to the inverter. They offer the following functions:
? Zero speed at full load torque
? Extremely accurate speed control
? Increased dynamic response of speed and torque control.
This module can be used with HTL and TTL pulse encoders (High voltage Transistor Logic, 24 V and Transistor Logic, 5 V).
Specifications:
Model PROFIBUS module6SE6400-1PB00-0AA0 Device Net module6SE6400-1DN00-0AA0
Size (height x width x depth) 161 mm x 73 mm x 46 mm
Degree of protection IP20
Degree of pollution 2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
Strain resistance to IEC 60 068-2-6 (if module is installed correctly)
• Stationary Deflection 0.15 mm in the frequency range of 10 Hz to 58 Hz
Acceleration 19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
•Transport Deflection 3.5 mm in the frequency range of 5 Hz to 9 Hz
Acceleration 9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
Climatic category (during operation) 3K3 to IEC 60 721-3-3
Cooling method Natural air cooling
Permissible ambient or cooling agent temperature
• Operation –10 °C to +50 °C (+14 °F to +122 °F)
• Storage and transport –25 °C to +70 °C (–13 °F to +158 °F)
Relative humidity (permissible
humidity rating)
• Operation ≤85 % (non-condensing)
• Storage and transport ≤95 %
Electromagnetic compatibility Emission to EN 55 011 (1991) Class A
Interference to IEC 60 801-3 and EN 61 000-4-3
Power supply 6.5 V ± 5 %, max. 300 mA, internal from inverter or 24 V ± 10 %, max. 350 mA, external 6.5 V ± 5 %, max. 300 mA internal from inverter or 24 V, max. 60 mA from Device Net-Bus
Output voltage 5 V ± 10 %, max. 100 mA, galvanically isolated supply• for terminating the serial interface bus or• for supplying the OLP (Optical Link Plug) –
Data transmission rate max. 12 Mbaud 125, 250 and 500 Kbaud