Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: 6ES7450-1AP00-0AE0
- Weight: 0.65kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
SIEMENS Counter Module 6ES7450-1AP00-0AE0
Product Description:
SIMATIC S7-400, FM 450-1 FUNCTION MODULE F. COUNT.FUNCT. WITH 2 CHANNELS INCL. CONFIG. PACKAGE ON CD.
Features:
Supply voltage | |
Load voltage 1L+ | |
Reverse polarity protection | Yes |
Load voltage 2L+ | |
Reverse polarity protection | Yes |
Aux. voltage 1L+, load voltage 2 L+ | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V; Dynamic 18.5 V |
permissible range, upper limit (DC) | 28.8 V; dynamic 30.2 V |
non-periodic skip | |
Duration | 500 ms |
Recovery time | 50 s |
Value | 35 V |
Input current | |
from load voltage 1L+ (without load), max. | 40 mA |
from backplane bus 5 V DC, max. | 450 mA |
Encoder supply | |
5 V encoder supply | |
5 V | Yes; 5.2 V +/-2% |
Short-circuit protection | Yes |
Output current, max. | 300 mA |
24 V encoder supply | |
24 V | Yes; 1L+ (-3 V) |
Short-circuit protection | Yes |
Output current, max. | 300 mA |
Power losses | |
Power loss, typ. | 9 W |
Digital inputs | |
Number/binary inputs | 6 |
Functions | 1 for gate start, 1 for gate stop, 1 for setting the counter |
Input voltage | |
for signal "0" | -28.8 to +5 V |
for signal "1" | +11 to +28.8 V |
Input current | |
for signal "1", typ. | 9 mA |
Input delay (for rated value of input voltage) | |
Input frequency (with a time delay of 0.1 ms), max. | 200 kHz |
for standard inputs | |
Parameterizable | Yes |
at "0" to "1", max. | 2.5 µs; >= 2.5 µs (200 kHz); <= 25 µs (20 kHz) |
Digital outputs | |
Number/binary outputs | 6 |
Functionality/short-circuit strength | Yes; Clocked electronically |
Limitation of inductive shutdown voltage to | 2L+ (-39 V) |
Output voltage | |
for signal "0", max. | 3 V |
for signal "1", min. | 2L+ (-1.5 V) |
Output current | |
for signal "1" rated value | 0.5 A |
for signal "1" permissible range for 0 to 60 °C, min. | 5 mA |
for signal "1" permissible range for 0 to 60 °C, max. | 0.6 A |
Output delay with resistive load | |
0 to | 300 µs |
Encoder | |
Connectable encoders | |
Incremental encoder (symmetrical) | Yes; With 2 pulse trains offset by 90° |
Incremental encoder (asymmetrical) | Yes |
24 V initiator | Yes |
24 V directional element | Yes; 1 pulse train, 1 direction level |
Interrupts/diagnostics/status information | |
Status indicator | Yes; 14 green LEDs for status of CR, DIR, inputs and outputs |
Alarms | |
Diagnostic alarm | Yes; Parameterizable |
Hardware interrupt | Yes; Parameterizable |
Diagnostic messages | |
Diagnostic functions | Yes |
Diagnostics | Yes; Diagnostic information readable |
Diagnostics indication LED | |
Description | 2 red LEDs for internal and external errors |
Status indicator digital output (green) | Yes |
Status indicator digital input (green) | Yes |
Counter | |
Number of counter inputs | 2; 32 bit or +/-31 bit |
Counter input 5 V | |
Type | RS 422 |
Terminating resistor | 220 Ω |
Differential input voltage | min. 0.5 V |
Counting frequency, max. | 500 kHz |
Counter input 24 V | |
Input voltage, for signal "0" | -30 to +5 V |
Input voltage, for signal "1" | +11 to +30 V |
Input current, for signal "1", typ. | 9 mA |
Counting frequency, max. | 200 kHz |
Minimum pulse width | >= 2.5 µs (200 kHz); <= 25 µs (20 kHz) (parameterizable) |
Parameter | |
Remark | Assigned binary addresses: 64 bytes/64 bytes |
Galvanic isolation | |
Galvanic isolation digital inputs | |
between the channels and the backplane bus | Yes; Optocoupler |
Galvanic isolation digital outputs | |
between the channels and the backplane bus | Yes; Optocoupler |
Galvanic isolation counter | |
between the channels and the backplane bus | Yes; Optocoupler |
Permissible potential difference | |
between different circuits | 75 VDC / 60 VAC |
Isolation | |
Isolation checked with | 500 V |
Connection method | |
required front connector | 1x 48-pin |
Dimensions | |
Width | 25 mm |
Height | 290 mm |
Depth | 210 mm |
Weight | |
Weight, approx. | 650 g |