Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: H5CX-L8D-N
- Weight: 0.12kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
OMRON Time Relay H5CX-L8D-N
Product Description:
DIN 48 × 48-mm Multifunction Digital Timer/2-stage Digital Timer
Specifications:
Accuracy of operating | Power-ON start: ±0.01% ±50 ms max. (See note 1.) | |
time and setting error | Signal start: ±0.005%±30 ms max. (See note 1.) | |
(including temperature | Signal start for transistor output model: ±0.005%±3 ms max. (See note 1 and 2.) | |
and voltage influences) | If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting time passes. | |
| Note: | |
| 1. The values are based on the set value. | |
| 2. The value is applied for a minimum pulse width of 1 ms. | |
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts | |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts | |
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits for the models other than H5CX-[]D-N | ||
1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuits for H5CX-[]SD-N | ||
2,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuits for other models | ||
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts | ||
Impulse withstand voltage | 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC | |
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC | ||
Noise immunity | ±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/ 1 μs, 1-ns rise) | |
Static immunity | Malfunction: 8 kV | |
Destruction: 15 kV | ||
Vibration | Destruction | 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each |
resistance | Malfunction | 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each |
Shock | Destruction | 300 m/s2 in three directions, three cycles |
resistance | Malfunction | 100 m/s2 in three directions, three cycles |
Life | Mechanical | 10,000,000 operations min. (under no load at 1,800 operations/h and ambient temperature of 23°C) |
expectancy | Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h and ambient temperature of 23°C) * |
Weight | Approx. 115 g (Timer only) | |