We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.

H3AM-NS-B AC100-240V Timer NEW

H3AM-NS-B AC100-240V Timer NEW
H3AM-NS-B AC100-240V Timer NEW
H3AM-NS-B AC100-240V Timer NEW
H3AM-NS-B AC100-240V Timer NEW
H3AM-NS-B AC100-240V Timer NEW
H3AM-NS-B AC100-240V OMRON Timer NEWOMRON Timer H3AM-NS-B AC100-240VProduct Description:Incorporatin... Read More
$281.00
Ex Tax: $281.00
  • Stock: In Stock
  • Model: H3AM-NS-B
  • Weight: 0.35kg
1. We typically ship items within three business days after payment is received.
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.

Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
We accept many payments,include Paypal,Bank Transfer etc
Tags: H3AM-NS-B
H3AM-NS-B AC100-240V OMRON Timer NEW

OMRON Timer H3AM-NS-B AC100-240V

Product Description:

Incorporating an easy-to-see large setting dial with moving pointers.

Wide time-setting range of 0.2 s to 60 h (available through three time-range model types)

Wide AC power supply range (100 to 240 VAC)

IP65 watertight and dust-tight front panel.

Approved by UL and CSA.

Conforms to EN61812-1 and IEC60664-14 kV for Low Voltage, and EMC Directives.

Conforms to EMC standards.

Six-language instruction manual provided.

Programmable contact enables the building of a self-holding relay circuit as well as built-in instantaneous contact. (-NS)

Memory retention (-NSR)

Finger protection terminal block

Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.

Specifications:

General

Operating mode

ON-delay

Screw tightening torque

0.98 Nm (10 kgf) max.

Input type

Voltage input

Output type

Relay: DPDT

Mounting method

Flush/Panel mounting, no restriction on mounting angle.

Approved standards

UL 508, CSA C22.2 No. 14

Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

Output category according to IEC60947-5-1

 

Time Ranges

Model

Full scale on

dial

Set time unit

s

10 s

min

10 min

h (hour)

10 h (hour)

H3AM-[][][]-A

3

---

0.5 to 30 s

0.05 to 3 min

0.5 to 30 min

0.05 to 3 h

0.5 to 30 h

H3AM-[][][]-B

6

---

1 to 60 s

0.1 to 6 min

1 to 60 min

0.1 to 6 h

1 to 60 h

H3AM-[][][]-C

12

0.2 to12 s

2 to 120 s

0.2 to 12 min

2 to 120 min

0.2 to 12 h

---

Note: Instantaneous output is obtained by turning the time setting knob below "0" until the time setting knob stops.

Ratings

Rated supply voltage

100 to 240 VAC (50/60 Hz)

Operating voltage range

85% to 110% of rated supply voltage

Power reset (-NS)

Minimum power-opening time: 0.5 s

Reset input time (-NSR)

Minimum input time: 0.5 s

Reset voltage range (-NSR)

H level: 85 to 264 VAC

L level: 0 to 10 VAC

Power consumption

Approx. 9 VA (Approx. 5 W)

Control output

Contact output: 5 A at 250 VAC, resistive load (cosΦ = 1)

Ambient temperature

Operating: -10°C to 55°C (with no icing)

Storage: -25°C to 65°C (with no icing)

Ambient humidity

Operating: 35% to 85%

Note:

The minimum applicable load:

H3AM-NS: 10 mA at 5 VDC (failure level: P, reference value)

H3AM-NSR: 100 mA at 5 VDC (failure level: P, reference value)

Characteristics

Accuracy of operating time

±0.7% FS max.

Setting error

±2% FS max.

Reset time

Power reset: 0.5 s max.

Reset input time: 0.5 s max.

Influence of voltage

±1% FS max.

Influence of temperature

±2% FS max.

Insulation resistance

100 MΩ max. (at 500 VDC)

Dielectric strength

2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts

2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals

1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)

1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other

2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles

Impulse withstand voltage

3 kV between power terminals

4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts

Noise immunity

±1.5 kV (between power terminals) square-wave noise by a noise simulator

(pulse width: 100 ns/1 μs, 1-ns rise)

Static immunity

Malfunction: 8 kV

Destruction: 15 kV

Vibration resistance

Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

Shock resistance

Destruction: 300 m/s2 3 times each in 6 directions

Malfunction: 150 m/s2 (100 m/s2 in the front/back direction) 3 times each in 6 directions

Life expectancy

Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)

Electrical: 100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)

Motor life expectancy

20,000 h

EMC

(EMI): EN61812-1

Emission Enclosure: EN55011 class A

Emission AC Mains: EN55011 class A

(EMS): EN61812-1

Immunity ESD: IEC61000-4-2: 6 kV contact discharge

8 kV air discharge

Immunity RF-interference: IEC61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)

10 V/m (Pulse-modulated, 900 MHz±5 MHz)

Immunity Power Frequency Magnetic Fields: IEC61000-4-8: 30 A/m (50 Hz)

Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz)

Immunity Burst: IEC61000-4-4: 2 kV power-line

2 kV I/O signal-line

Immunity Surge: IEC61000-4-5: 1 kV line to line

2 kV line to ground

Enclosure rating

IP65 (front panel only) (See note.) IP20 (terminal section)

Weight

Approx. 350 g

Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.