Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: E2A-M18LS08-WP-B1
- Weight: 0.16kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
Product Description:
Safe Mounting with Greater Sensing Distance
• Ensures a sensing distance approximately 1.5 to 2m times larger than that of any conventional OMRON Sensor.
• Problems such as the collision of workpieces are eliminated.
• Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels)
• Modular construction simplifies customization.
Specifications:
Size | M18 | M30 | |||
Type | Shielded | Non-shielded | Shielded | Non-shielded | Non-shielded |
Item | E2A-M18?S08-??-B? | E2A-M18?N16-??-B? | E2A-M30?S15-??-B? | E2A-M30KN20-??-B? | E2A-M30LN30-??-B? |
Sensing distance | 8 mm±10% | 16 mm±10% | 15 mm±10% | 20 mm±10% | 30 mm±10% |
Setting distance | 0 to 6.4 mm | 0 to 12.8 mm | 0 to 12 mm | 0 to 16 mm | 0 to 24 mm |
Differential travel | 10% max. of sensing distance | ||||
Target | Ferrous metal (The sensing distance decreases with non-ferrous metal.) | ||||
Standard target (mild steel ST37) | 24×24×1 mm | 48×48×1 mm | 45×45×1 mm | 60×60×1 mm | 90×90×1 mm |
Response frequency (See note 1.) | 500 Hz | 400 Hz | 250 Hz | 100 Hz | 100 Hz |
Power supply voltage (operating voltage range) | 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) | ||||
Current consumption (DC 3-wire) | 10 mA max. | ||||
Output type | -B models: PNP open collector -C models: NPN open collector | ||||
Load current (See note 2.) | Load current (See note 2.) | ||||
Residual voltage | 2 V max. (under load current of 200 mA with cable length of 2 m) | ||||
Indicator | Operation indicator (Yellow LED) | ||||
Operation mode (with sensing object approaching) | -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. | ||||
Protection circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection | ||||
Ambient air temperature | Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation) | ||||
Temperature influence (See note 2.) | ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C | ||||
Ambient humidity | Operating: 35% to 95%, Storage: 35% to 95% | ||||
Voltage influence | ±1% max. of sensing distance in rated voltage range ±15% | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current carry parts and case | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case | ||||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | 1,000 m/s2, 10 times each in X, Y and Z directions | ||||
Standard and listings | IEC60529: IP67, Degree of protection EN60947-5-2: EMC UL (CSA) [E196555] (See note 3.) | ||||
Connection method | -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models | ||||
Weight (packaged) Pre-wired model | Approx. 160 g | Approx. 280 g | Approx. 280 g | Approx. 370 g | |
Weight M12 connector model | Approx. 70 g | Approx. 200 g | Approx. 200 g | Approx. 260 g | |
Case | Brass-nickel plated | ||||
Sensing surface | PBT | ||||
Cable | PVC | ||||
Clamping nut | Brass-nickel plated | ||||
Note:
1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.,
3. UL (CSA) [E196555]: Use class 2 circuit only.