Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: VM05-11K
- Weight: 8.00kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.
VM05-2.2K Sanken Inverter SRMCO-VM05 series
The High-end Inverter
Overview:
The SAMCO-vm05 Series of general-purpose inverters boasts revolutionary performance born from Sanken's superlative technological capabilities.
To meet diversified needs, the SAMCO-vm05 Series offers a powerful array of features, including dual-rated specifications selectable to best suit the intended application, the industry's first software customization function, and control algorithms provided as standard.
Dual-rated specifications for cost reduction
Two types of rated specifications - H characteristic and P characteristic can be selected according to the load status, for a wider range of standard applicable motors and substantial cost reduction (200 V type STB Series).
Industry's first software customize function
Dedicated functions can be created by adding various types of software, according to the customer's requirements. Users can also perform program changes and upgrades following purchase.
Control algorithms for various types of applications provided as standard
Control algorithms for diverse applications, such as winding control, multiple pump drive control and fixed-time inching, are provided as standard. This can be used as a dedicated inverter to meet diversified system needs.
Operability and communication functions developed with ease of use
The RS-232C interface, allowing direct connection to personal computers, and the RS-485 interface, effective in operation management in a system, are provided as standard.
Expandability with PG feedback
Vector control operation is realized through a PG feedback board (option).
Specifications:
Model | SBT- | SBT- | SBT- | SBT- | SBT- | SBT- | SBT- | SBT- | SBT- | SBT- | |||||||||||||||||||||||||||||
|
| H | P | H | P | H | P | H | P | H | P | H | P | H | P | H | P | H | P | H | P | ||||||||||||||||||
| 0.75 | 1.5 | 1.5 | 2.2 | 2.2 | 3.7 | 3.7 | 5.5 | 5.5 | 7.5 | 7.5 | 11 | 11 | 15 | 15 | 18.5 | 18.5 | 22 | 22 | 30 | |||||||||||||||||||
| 1.9 | 2.7 | 3.0 | 3.7 | 4.3 | 5.8 | 6.7 | 8.5 | 9.1 | 11.4 | 12.8 | 16.8 | 17.5 | 21.7 | 22.9 | 25.9 | 28.6 | 31.2 | 33.5 | 41.9 | |||||||||||||||||||
| 5.1 | 7.0 | 8.0 | 9.6 | 11.2 | 15.1 | 17.6 | 22.3 | 24 | 30 | 33 | 44 | 46 | 57 | 60 | 68 | 75 | 82 | 88 | 110 | |||||||||||||||||||
Output | Load*1 | 8.4 | 12.0 | 11.5 | 16.8 | 18.1 | 26.4 | 26.7 | 36 | 36 | 49.5 | 52.8 | 69 | 68.4 | 90 | 81.6 | 112.5 | 98.4 | 132 | 132 | |||||||||||||||||||
Input |
| Applicable | 200V 50/60Hz 220V 60Hz | ||||||||||||||||||||||||||||||||||||
| Rated | 3φ 200V to 230V 50/60Hz | |||||||||||||||||||||||||||||||||||||
| Rated | Voltage: ±10%, | |||||||||||||||||||||||||||||||||||||
| Overload | 1% or more (Use the optional reactor if less than 1%) | |||||||||||||||||||||||||||||||||||||
Protective | Shutdown method (IP20) | ||||||||||||||||||||||||||||||||||||||
Cooling | Self-cooling | Forced air cooling | |||||||||||||||||||||||||||||||||||||
Gross | 3kg | 4kg | 4kg | 4.5kg | 8kg | 8kg | 10kg | 12kg | 15kg | 18kg | |||||||||||||||||||||||||||||
Control | Control | V/f control or sensorless vector control | |||||||||||||||||||||||||||||||||||||
High-frequency | Sine wave PWM (carrier frequency: 1 to 14 kHz)*4 | ||||||||||||||||||||||||||||||||||||||
Output | H | 0.05 to 600 Hz (starting frequency: 0.05 to 20 Hz, variable)*5 | |||||||||||||||||||||||||||||||||||||
P | 0.01Hz (0.05 to 600Hz) | ||||||||||||||||||||||||||||||||||||||
Frequency | Digital | 0.01 Hz (0.05 to 600 Hz) | |||||||||||||||||||||||||||||||||||||
Analog | 0.1% (10 bits for 0 to 10 V, 4 to 20 mA), 0.2% (9 bits for 0 to 5 V) for maximum output frequency | ||||||||||||||||||||||||||||||||||||||
Frequency | Digital | ±0.01% of output frequency (at 10 to 40°C) | |||||||||||||||||||||||||||||||||||||
Analog | ±0.2% of maximum output frequency (at 25°C ±10°C)*6 | ||||||||||||||||||||||||||||||||||||||
DC braking | Starting frequency (0.2 to 20 Hz), operation time (0.1 to 10 s), braking force (1 to 10 steps) | ||||||||||||||||||||||||||||||||||||||
Additional | Restart after momentary power failure, scooping-up start, multi-speed operation, frequency jump, auto alarm recovery, | ||||||||||||||||||||||||||||||||||||||
Operational | Start/ | Operation panel, serial communication (RS485, RS232C), control circuit terminals | |||||||||||||||||||||||||||||||||||||
Frequency | Digital | Operation panel, serial communication (RS485, RS232C), step setting from terminal board | |||||||||||||||||||||||||||||||||||||
Analog | 2 external channels: 0 to 5 V, 0 to 10 V, 4 to 20 mA, external variable resistor (5 kΩ , 0.3 W or higher) | ||||||||||||||||||||||||||||||||||||||
Input signals | Frequency command, forward run command, reverse run command, acceleration/ | ||||||||||||||||||||||||||||||||||||||
| Contact | Alarm batch and multifunctional contact output (1C contact, 250 VAC, 0.3 A) | |||||||||||||||||||||||||||||||||||||
Monitor | Operating, frequency matching, overload alarm, undervoltage, frequency approach | ||||||||||||||||||||||||||||||||||||||
Output | Frequency, output current, number of synchronous rotations, load factor, output voltage, pressure, line speed (no units), operating, alarm | ||||||||||||||||||||||||||||||||||||||
Serial | RS485, RS232C | ||||||||||||||||||||||||||||||||||||||
Function | Software upgrade via RS232C serial communication supported | ||||||||||||||||||||||||||||||||||||||
External power | 24 VDC, 150 mA (control terminal board) | ||||||||||||||||||||||||||||||||||||||
Protection | Current limiting, overcurrent shutoff, motor overload, external temperature, | ||||||||||||||||||||||||||||||||||||||
Warning | Overvoltage prevention, current limiting during acceleration/deceleration, brake resistor overheat, overload, overheating of radiator fins | ||||||||||||||||||||||||||||||||||||||
Environment | Ambient | H | -10 to +50°C (Top ventilation cover to be removed at +40°C and higher) | ||||||||||||||||||||||||||||||||||||
P | 10 to +40°C (Top ventilation cover to be removed at +30°C and higher for SBT-3.7K/5.5K and earlier models) | ||||||||||||||||||||||||||||||||||||||
Storage | -20 to +65°C*7 | ||||||||||||||||||||||||||||||||||||||
Relative | 90% or less (with no condensation) | ||||||||||||||||||||||||||||||||||||||
Operating | Indoors at 1,000 m or lower altitude (No direct sunlight, | ||||||||||||||||||||||||||||||||||||||
1 H: H characteristic - Constant torque load (for general industry),
P: P characteristic - Dual law decreasing torque load (for fans and pumps)
2 Rated capacity at an output voltage of 220 V
3 1 minute every 10 minutes
4 The maximum carrier frequency varies depending on the rated characteristics and the operating status.
5 The frequency setting range for sensorless vector control is 1 to 130 Hz for a four-pole motor (depends on the number of poles).
6 The maximum output frequency is at 5 V, 10 V, and 20 mA.
7 This temperature is for short periods, such as during transportation.
The SBT-7.5K/11K and earlier models are equipped with discharge resistors as stanuipped with discharge resistors as standard.