Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: 6ES7314-1AG14-0AB0
- Weight: 0.28kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
SIEMENS CPU Module 6ES7314-1AG14-0AB0
Product Description:
SIMATIC S7-300, CPU 314 CPU WITH MPI INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, MICRO MEMORY CARD NECESSARY.
Features:
General information | |
Hardware product version | 01 |
Firmware version | V2.0.0 |
Engineering with | |
Programming package | STEP 7 V5.1 SP4 or higher |
Supply voltage | |
24 V DC | Yes |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
External protection for supply cables (recommendation) | 2 A min. |
Input current | |
Current consumption (in no-load operation), typ. | 60 mA |
Inrush current, typ. | 2.5 A |
I²t | 0.5 A²·s |
from supply voltage L+, max. | 600 mA |
Power losses | |
Power loss, typ. | 2.5 W |
Backup battery | |
Battery operation |
|
Backup time, max. | 1008 h; At 40 °C ambient temperature |
Memory | |
Work memory | |
integrated | 48 kbyte |
expandable | No |
Load memory | |
pluggable (MMC) | Yes |
pluggable (MMC), max. | 8 Mbyte |
Data management on MMC (after last programming), min. | 10 a |
Backup | |
present | Yes; Guaranteed by MMC (maintenance-free) |
CPU processing times | |
for bit operations, min. | 0.1 µs |
for bit operations, max. | 0.2 µs |
for word operations, min. | 0.2 µs |
for fixed point arithmetic, min. | 2 µs |
for floating point arithmetic, min. | 3 µs |
CPU-blocks | |
Number of blocks (total) | 1024; (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used. |
DB | |
Number, max. | 511; DB 0 reserved |
Size, max. | 16 kbyte |
FB | |
Number, max. | 512; From FB 0 to FB 511 |
Size, max. | 16 kbyte |
FC | |
Number, max. | 512; from FC 0 to FC 511 |
Size, max. | 16 kbyte |
OB | |
Number, max. | see instruction list |
Size, max. | 16 kbyte |
Nesting depth | |
per priority class | 8 |
additional within an error OB | 4 |
Counters, timers and their retentivity | |
S7 counter | |
Number | 256 |
of which retentive without battery | |
adjustable | Yes |
preset | Z 0 to Z 7 |
Retentivity | |
adjustable | Yes |
Counting range | |
adjustable | Yes |
lower limit | 0 |
upper limit | 999 |
IEC counter | |
present | Yes |
Type | SFB |
Number | Unlimited (limited only by RAM capacity) |
S7 times | |
Number | 256 |
Retentivity | |
adjustable | Yes |
preset | No retentivity |
Time range | |
lower limit | 10 ms |
upper limit | 9990 s |
IEC timer | |
present | Yes |
Type | SFB |
Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity | |
retentive data area, total | All (incl. memory bits, times, counters) |
Flag | |
Number, max. | 256 byte |
Retentivity available | Yes; MB 0 to MB 255 |
Retentivity preset | MB 0 to MB 15 |
Number of clock memories | 8; 1 memory byte |
Data blocks | |
Number, max. | 511; from DB1 to DB511 |
Size, max. | 16 kbyte |
Local data | |
per priority class, max. | 510 byte |
Address area | |
I/O address area | |
Inputs | 1 kbyte |
Outputs | 1 kbyte |
Process image | |
Inputs | 128 byte |
Outputs | 128 byte |
Digital channels | |
Inputs | 1024 |
Outputs | 1024 |
Inputs, of which central | 1024 |
Outputs, of which central | 1024 |
Analog channels | |
Inputs | 256 |
Outputs | 256 |
Inputs, of which central | 256 |
Outputs, of which central | 256 |
Hardware configuration | |
Racks, max. | 4 |
Modules per rack, max. | 8 |
Number of DP masters | |
integrated | 0 |
via CP | 4 |
Number of operable FMs and CPs (recommended) | |
FM | 8 |
CP, point-to-point | 8 |
CP, LAN | 10 |
Time of day | |
Clock | |
Hardware clock (real-time clock) | Yes |
battery-backed and synchronizable | Yes |
Deviation per day, max. | 10 s |
Backup time | 6 wk; At 40 °C ambient temperature |
Operating hours counter | |
Number | 1 |
Number/Number range | 0 |
Range of values | 0 to 2^31 hours (when using SFC 101) |
Granularity | 1 hour |
retentive | Yes; Must be restarted at each restart |
Clock synchronization | |
supported | Yes |
to MPI, master | Yes |
to MPI, slave | Yes |
in AS, master | Yes |
Analog inputs | |
Integrated channels (AI) | 0 |
Analog outputs | |
Integrated channels (AO) | 0 |
1st interface | |
Type of interface | Integrated RS 485 interface |
Physics | RS 485 |
Isolated | No |
Power supply to interface (15 to 30 V DC), max. | 200 mA |
Functionality | |
MPI | Yes |
DP master | No |
DP slave | No |
Point-to-point connection | No |
MPI | |
Number of connections | 12 |
Services | |
PG/OP communication | Yes |
Routing | No |
Global data communication | Yes |
S7 basic communication | Yes |
S7 communication | Yes |
S7 communication, as client | No; but via CP and loadable FB |
S7 communication, as server | Yes |
Transmission rate, max. | 187.5 kbit/s |
Communication functions | |
PG/OP communication | Yes |
Global data communication | |
supported | Yes |
Number of GD loops, max. | 4 |
Number of GD packets, max. | 4 |
Number of GD packets, transmitter, max. | 4 |
Number of GD packets, receiver, max. | 4 |
Size of GD packets, max. | 22 byte |
Size of GD packet (of which consistent), max. | 22 byte |
S7 basic communication | |
supported | Yes |
User data per job, max. | 76 byte |