Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: AFPX-E30R
- Weight: 0.50kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
FP-X E30R AFPX-E30R Panasonic PLC 100~240VAC 16-point input 14-point relayoutput FP-X Expansion Unit Original New
Features
High-speed Operation
The 32-bit RISC processor provides the top-level processing speed in compact PLCs. The scan time is 2 ms or less for 5,000 steps*1. A high-speed PLC is indispensable for enhancing the functionality of equipment.
Large Capacity Program Memory
FP-X, which is equipped with 32k steps*2 program memory, is ideal for fully covering the increasing functions, such as communications, positioning, and analog control. The sufficient program capacity can also support future equipment modifications.
Independent Comment Memory
There are difficulties with program management on a PC, such as identifying the latest program. The use of the program in the PLC of equipment in operation is often regarded as the best option. Since FP-X has an independent comment memory, all comments can be stored in the PLC together with programs, facilitating program management and maintenance.
Maximum Number of I/O Points
Since up to eight expansion units can be connected to one control unit, the maximum number of I/O points is 300. Furthermore, with the add-on cassette and expansion FP0 adapter connected, the number of I/O points can be increased to 382.
*1 Basic instructions: 40%, Data transfer and operation instructions: 60%
*2 C14: 16k steps
Specifications
Item | Description | |||
Relay output type | Transistor output type | |||
Power supply and I/O Specifications | Power supply | 100 to 240 V AC (AC power), 24 V DC (DC power) | ||
Input | 24V DC °C common | |||
Output | 2 A | 0.5 A | ||
Service power supply | 0.15 A (C14)/ 0.4 A (C30/ C60) | |||
Performance Specifications | Number of I/O points | C14 | Input: 8 points, Output: 6 points | |
C30 | Input: 16 points, Output: 14 points | |||
C60 | Input: 32 points, Output: 28 points | |||
I/O points when expanded | C14 | Max. 328 points (When using FP0 expnasion unita and add-on cassette) | ||
C30 | Max. 352 points (When using FP0 expnasion unita and add-on cassette) | |||
C60 | Max. 382 points (When using FP0 expnasion unita and add-on cassette) | |||
Operation speed | 0.32μs/step | |||
Program memory | Flash ROM built-in (no battery backup required) | |||
Program capcity | 16 ksteps (C14), 32 ksteps (C30, C60) | |||
Basic instructions | 111 | |||
Applied instructions | 216 | |||
Operation memory | Internal relay ® | 4096 points | ||
Timer/counter (T/C) | 1024 points | |||
Data register (DT) | 256 words | |||
Special functions | Pulse catch input | 14 points | 14 points | |
Interrupt input | 14 points | 14 points | ||
Analog I/O | Input: Max. 24 ch, Output: Max. 12 ch (When using FP0 analog unit) | |||
Volume input | 2 points (C14/C30), 4 points (C60) | |||
High-speed counter | Input of main unit | Single-phase: 8 ch x Max. 10 kHz | Single-phase: 8 ch (High-speed: 4 ch, midium-speed: 4 ch) | |
when pulse I/Ocassette installed | Single-phase: 2 ch x Max. 80 kHz, 4 ch x Max. 50 kHz | Pulse I/O cassette cannot be installed. | ||
Pulse output | Input of main unit | - | With high-speed 2 ch x Max. 100 kHz | |
when pulse I/Ocassette installed | 1 ch x Max. 100 kHz, 2ch x Max. 80 kHz | Pulse I/O cassette cannot be installed. | ||
Serial interface | RS232C.RS485, USB, Ethernet | |||
Network function | PLC Link, Computer link, Modem, Modbus-RTU | |||
Other functions | Program editing during RUN, Constant scan, 8-digit password, Program | |||
Input Unit / Output unit
Product name | Power supply | Specifications | Part number |
FP-X E16X | - | 24 V DC, 16 input points *1 | AFPX-E16X |
FP-X E14YR | - | 2A relay, 14 output points *1 | AFPX-E14YR |
I/O Unit (Relay output)
Product name | Power supply | Specifications | Part number |
FP-X E16R | - | 8-point input of 24 V DC, | AFPX-E16R |
FP-X E30R | 100~240V AC | 16-point input of 24 V DC, | AFPX-E30R |
FP-X E30RD | 24V DC | 16-point input of 24 V DC, | AFPX-E30RD |
I/O Unit (Transistor output)
Product name | Power supply | Specifications | Part number |
FP-X E16T | - | 8-point input of 24 V DC, | AFPX-E16T |
FP-X E16P | - | 8-point input of 24 V DC, | AFPX-E16P |
FP-X E30TD | 24V DC | 16-point input of 24 V DC, | AFPX-E30TD |
FP-X E30T | 100~240V AC | 16-point input of 24 V DC, | AFPX-E30T |
FP-X E30PD | 24V DC | 16-point input of 24 V DC, | AFPX-E30PD |
FP-X E30P | 100~240V AC | 16-point input of 24 V DC, | AFPX-E30P |