Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: K7M-DR40U
- Weight: 1.50kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
PLCAGE: K7M-DR40U LS(LG) PLC K120S Series Standard Type 24 DC Inputs(24VDC) 16 Relay Outputs 85~264VAC New
Features:
Powerful built-in functions
* High-speed counter: 32-bit signed operation,
- Counter range: -2,147,483,648~2,147,483,647
- Function: ring counter,latch counter,comparison(equal/zone/task),RPM
* Positioning function(DRT/DT type)
- Control axis: 2 axes(100kHz)
- Operation method: single,repeat
- Operation mode: end,keep,continuous
- Additional functions: return to origin,JOG operation,PWM output
* PID operation function
- Relay/PRC auto-tuning,SV ramp,delta MV,PWM output,position/velocity algorithm
Various expansion modules
* 7 Digital I/O modules: G7E-DR(08/10/20)A,G7E-TR10A,G7E-DC08A,G7E-RY(08/16)A
* 9 Analog I/O modules: G7F-ADHA(B/C),G7F-AD2A(B),G7F-DA2I(V),G7F-AT2A,
G7F-RD2A
* 6 Comm. modules: G7L-CUEB(C),G7L-DBEA,G7L-PBEA,G7L-FUEA,G7L-RUEA
* 2 Option modules: G7E-RTCA,G7M-M256B
K120S Series System Equipment Product:
Main Unit – Standard type
Items | Models | I/O Point & Power Supply | Built-in Function |
Main Unit | K7M-DR20U | 12 DC inputs(24VDC) 8 relay outputs 85~264 VAC | • Program capacity: 10 k steps• Max. expansion: 3 modules• High-speed counter: - 1 Phase: 100 kHz 1channel, 20 kHz 2channel. - 2 Phase: 50 kHz 1channel, 10 kHz 1channel. • Pulse catch: pulse width 10us 2 points, 50us 6 points,• External interrupt:: 10us 2 points, 50us 6 points• Input filter: 0~1000ms(can be designated with groups)• PID control function• RS-232C communication, RS-485 communication |
K7M-DR30U | 18 DC inputs(24VDC) 12 relay outputs 85~264 VAC | ||
K7M-DR40U | 24 DC inputs(24VDC) 16 relay outputs 85~264 VAC | ||
K7M-DR60U | 36 DC inputs(24VDC) 24 relay outputs 85~264 VAC | ||
K7MDRT/DT20U | 12 DC inputs(24VDC) 4/0 relay outputs 4/8 TR outputs 85~264 VAC | • Program capacity: 10 k steps• Max. expansion: 3 modules• High-speed counter: - 1 Phase: 100 kHz 1channel, 20 kHz 2channel. - 2 Phase: 50 kHz 1channel, 10 kHz 1channel. • Pulse catch: pulse width 10us- 2 points, 50us-6 points,• External interrupt: 10us- 2 points, 50us- 6 points• Input filter: 0~1000ms(can be designated with groups)• PID control function• RS-232C communication, RS-485 communication• Positioning function- 2axes 100 kpps - Absolute/Incremental positioning method - Single/Repeat operation method - End/Keep/Continuous mode - Return to origin, JOG, PWM, velocity control | |
K7MDRT/DT30U | 18 DC inputs(24VDC) 8/0 relay outputs 4/12 TR outputs 85~264 VAC | ||
K7MDRT/DT40U | 24 DC inputs(24VDC) 12/0 relay outputs 4/16 TR outputs 85~264 VAC | ||
K7MDRT/DT60U | 36 DC inputs(24VDC) 20/0 relay outputs 4/24 TR outputs 85~264 VAC |
Specifications:
Item | Specifications | Remark | |||||
K7M-DR/DRT/DT20U(/DC) | K7M-DR/DRT/DT30U (/DC) | K7M-DR/DRT/DT40U (/DC) | K7M-DR/DRT/DT60U (/DC) | ||||
Operation method | Cyclic execution of stored program, Time-driven interrupt, Process-driven interrupt |
| |||||
I/O control method | Refresh method, Direct method by command |
| |||||
Program language | Instruction list, Ladder diagram |
| |||||
Number of instructions | Basic | 30 |
| ||||
Application | 277 |
| |||||
Processing speed | 0.1us/step |
| |||||
Program memory capacity | 10k steps |
| |||||
I/O points | Input | 12 | 18 | 24 | 36 |
| |
Output | 8 | 12 | 16 | 24 |
| ||
Data area | P | P000~P63F | I/O relay | ||||
M | M000~M191F | Auxiliary relay | |||||
K | K000~K31F | Keep relay | |||||
L | L000~L63F | Link relay | |||||
F | F000~F63F | Special relay | |||||
T | 100ms: T000~T191(192 points), 10ms: T192~T250(59 points) | Timer | |||||
C | 1ms: T251~T255(5 points), Adjustable by parameter setting | Counter | |||||
S | C000~C255 | Step controller | |||||
D | S00.00~S99.99 | Data register | |||||
Operation mode | D0000~D4999 |
| |||||
Self-diagnostic function | Run, Stop, Pause, Debug |
| |||||
Data back-up method | Scan time, memory, I/O, and power supply error detection |
| |||||
Max. expansion stage | Program: EEPROM, Data: Super-capacitor |
| |||||